title: "2.4.2 Create & publish a register template"
description: "How the System Admin builds a register — defining the Details (once-per-log) fields and the Table (repeating-row) columns, choosing field types, then publishing it Live so it can be filled. Includes a worked Concrete Pour Register example."
url: https://help.digiqc.com/en/articles/212-242-create-and-publish-a-register-template
collection: "2.4 Register"
updated: 2026-11-05
language: en
---

# 2.4.2 Create & publish a register template

How the System Admin builds a register — defining the Details (once-per-log) fields and the Table (repeating-row) columns, choosing field types, then publishing it Live so it can be filled. Includes a worked Concrete Pour Register example.

### Overview

A register starts as a **template** — its structure. Only the **System Admin** creates it: you define the **Detail section** (filled once per log) and the **Table** section (repeating rows), choose the **field types**, then **Go live** so Inspectors and Project Admins can prepare a log.

### 🧭 How to use

1.  **Create the template.** In Register, create a new template and name it — e.g. _Concrete Pour Register_. It is saved as **Draft.**
    
2.  **Define the Detail section** — single-value header fields filled **once per log:**
    

<table style="min-width: 50px;"><colgroup><col style="min-width: 25px;"><col style="min-width: 25px;"></colgroup><tbody><tr><th colspan="1" rowspan="1"><p>Field</p></th><th colspan="1" rowspan="1"><p>Type</p></th></tr><tr><td colspan="1" rowspan="1"><p>Vendor</p></td><td colspan="1" rowspan="1"><p>Text</p></td></tr><tr><td colspan="1" rowspan="1"><p>Concrete Grade</p></td><td colspan="1" rowspan="1"><p>Option (M20, M25, M30, M35)</p></td></tr><tr><td colspan="1" rowspan="1"><p>Pour Location</p></td><td colspan="1" rowspan="1"><p>Nomenclature</p></td></tr><tr><td colspan="1" rowspan="1"><p>Pour Date</p></td><td colspan="1" rowspan="1"><p>Date</p></td></tr><tr><td colspan="1" rowspan="1"><p>Supervisor Name</p></td><td colspan="1" rowspan="1"><p>Text</p></td></tr><tr><td colspan="1" rowspan="1"><p>Linked inspection</p></td><td colspan="1" rowspan="1"><p>EQC Link</p></td></tr></tbody></table>

\- **Nomenclature field:** the person preparing the log picks from the project's nomenclature tree list (e.g. Tower A → Level 3 → Column). On a **Flexible** project they can also type their own name, but they do not have to (see 2.5.37). The L0 Project Code is auto-filled. - **EQC Link field:** links the log to one or more inspections, which open directly from the register.

1.  **Define the Table section** — columns for repeating rows (each row = one Entry):
    

<table style="min-width: 50px;"><colgroup><col style="min-width: 25px;"><col style="min-width: 25px;"></colgroup><tbody><tr><th colspan="1" rowspan="1"><p>Column</p></th><th colspan="1" rowspan="1"><p>Type</p></th></tr><tr><td colspan="1" rowspan="1"><p>Date</p></td><td colspan="1" rowspan="1"><p>Date</p></td></tr><tr><td colspan="1" rowspan="1"><p>Batch No.</p></td><td colspan="1" rowspan="1"><p>Text</p></td></tr><tr><td colspan="1" rowspan="1"><p>Qty (cum)</p></td><td colspan="1" rowspan="1"><p>Numeric</p></td></tr><tr><td colspan="1" rowspan="1"><p>Vehicle No.</p></td><td colspan="1" rowspan="1"><p>Text</p></td></tr><tr><td colspan="1" rowspan="1"><p>Test Cube No.</p></td><td colspan="1" rowspan="1"><p>Text</p></td></tr><tr><td colspan="1" rowspan="1"><p>Slump (mm)</p></td><td colspan="1" rowspan="1"><p>Numeric</p></td></tr><tr><td colspan="1" rowspan="1"><p>Total Qty</p></td><td colspan="1" rowspan="1"><p>Calculation (Total of Qty)</p></td></tr><tr><td colspan="1" rowspan="1"><p>Remark</p></td><td colspan="1" rowspan="1"><p>Multi-line Text</p></td></tr></tbody></table>

_Note: Nomenclature and EQC Link are Detail section only — they can't be added to the Table section._

1.  **Validate & publish to Live.** Review all field names, types, and calculation formulas, then **publish.** The register becomes **Live** and available for preparing logs.
    
2.  **Archive when no longer needed.** Archiving stops new logs; historical logs stay for view/export. A register **cannot return to Live** once archived.
    

### ❓ FAQ

#### 1\. Who can create a register template?

Only the **System Admin.** Project Admins cannot create or edit templates.

#### 2\. Can I change a template after publishing it?

You can **add or remove fields**, but you **cannot change a field's type, label, or formula** once it's Live — so plan carefully before publishing.

#### 3\. How do I add a location field?

Use a **Nomenclature** field (Detail section only) — it links to the project's nomenclature tree list, and on a **Flexible** project the person preparing the log can also type their own name.

#### 4\. How do I link inspections to a register?

Use an **EQC Link** field (Detail section only) — the person preparing the log can attach one or more inspections that open directly from the register.

#### 5\. How do I auto-total a column?

Use a **Calculation** field — e.g. _Total Qty = Total of the Qty column._ Calculation fields compute automatically; no manual entry.

#### 6\. Can I un-archive a register?

No. **Archive is final** — historical logs remain available for view and export, but no new logs can be prepared on it.

#### Can I stop negative numbers in a Register's Numeric field?

Yes. In a **Register** template, each **Numeric** field has an advanced **Allow Negative Number** setting, **ON by default.** Turn it **OFF** so the field accepts only **zero and positive numbers** — **decimals are still allowed** and **0 is always allowed.** Only a **System Admin** can set it; it works on both the **Detail** and **Table** parts of the register. You can change it on a **live register template** — it **does not re-check data already saved**, and applies only to **new entries.** While preparing the log, a blocked negative value shows an **instant message under the cell** to fix before saving.

#### Can a Date or Time field in a Register fill in automatically?

Yes. In a **Register** template, each **Date** field and each **Time** field has an advanced setting to **auto-fill the current date/time when the log is prepared** — it is **OFF by default.** When turned on, the field is **stamped automatically**, but the value **stays editable** if you need to correct it. The stamp uses **server time shown in the project's time zone**, so everyone on the project gets one consistent, trustworthy time. Only a **System Admin** sets it (Date and Time can be turned on independently); it works on both the **Detail** and **Table** parts of the register, on a **live template**, applying only to **new entries/rows.**

### 💡 Good to know

-   Only the **System Admin** creates, publishes, and archives templates.
    
-   A field's **type, label, and formula are locked after publishing** — only add/remove is allowed.
    
-   **Nomenclature** and **EQC Link** are **Detail section only.**
    
-   The lifecycle is **Draft → Live → Archive** only.
    
-   There are two register types. This article covers Running Entries, where the person preparing the log adds rows as the work goes. For a register with a fixed, printed shape, see 2.4.9 Build a Fixed Entries register.
    

-   In a **Register**, **Numeric fields** can be restricted to **non-negative** values via the **Allow Negative Number** setting (System Admin) — decimals and 0 stay allowed.
    
-   In a **Register**, **Date/Time fields** can **auto-stamp** the current **project-time** when the log is prepared (System Admin) — the stamped value is still **editable.**
    

### 🔗 Related articles

-   2.4.1 Register — overview & key concepts
    
-   2.4.3 Prepare a register log — logs & entries
    
-   2.4.4 Set up register verifications — submissions and verification levels
    
-   2.4.5 View & export register data
    
-   2.4.9 Build a Fixed Entries register