description: "Design a unique auto RFI number from parts (project, checklist, date/time, running Number, nomenclature L1-L7). Number part mandatory; each part once; sequential across checklists; new number on Fail/Redo; format locks after first RFI; available only if digiQC grants the right and RFI is on."
url: https://help.digiqc.com/en/articles/264-2527-how-to-set-up-rfi-auto-numbering
collection: "2.5 Web Setup, Monitoring, Tracking and Analysis"
updated: 2026-11-05
language: en
---

# 2.5.27 How to set up RFI auto-numbering?

Design a unique auto RFI number from parts (project, checklist, date/time, running Number, nomenclature L1-L7). Number part mandatory; each part once; sequential across checklists; new number on Fail/Redo; format locks after first RFI; available only if digiQC grants the right and RFI is on.

### Overview

RFI auto-numbering gives every RFI a **unique number in a format you design** — so no one numbers RFIs by hand. You build the number from ready-made parts (project, checklist, date/time, a running number, nomenclature levels).

This option is available **only if the digiQC team has given your organisation the right.** Once available, it can be used **only when RFI is switched on for the project** (project settings).

### 🧭 How to use

1.  Make sure **RFI is on** for the project.
    
2.  Open the **RFI numbering** setup.
    
3.  Build the number using **up to 7 parts**, in the order you want, from:
    

\- **Project** — Project Name, Project Code - **Checklist** — Checklist Name, Checklist Stage, Reference Number - **Date & Time** — Full Date (DDMMYYYY), Long Date (DD-MM-YYYY), Date (DD), Month (MM), Year (YY), Time (HH:mm, 24hr) - **Sequence** — Number _(the running serial)_ - **Nomenclature Levels** — Nomenclature L1 to L7

1.  The **Number** part is **mandatory** — you can't save without it.
    
2.  Set the **Start value** for the Number if you want the sequence to begin from a specific figure _(useful when adopting it mid-project)_. Default is **1**.
    
3.  **Save.**
    

### 🔁 What happens on Fail or Redo

If an RFI is **re-raised because the inspection was Failed or sent for Redo**, digiQC **does not reuse the old RFI number.** A **new RFI number is assigned**, taking the **next available number in the sequence.**

So every attempt gets its **own unique RFI number**, and the sequence keeps moving forward — you can always tell a re-raised RFI apart from the original.

### ❓ FAQ

**Why can't I see RFI auto-numbering?** It's available only if **digiQC has given your organisation the right,** and only when **RFI is on** for the project.

**Is the Number part compulsory?** Yes — the format **cannot be saved** without the **Number** part.

**Can I start numbering from a specific figure?** Yes — set the **Start value** (e.g. begin at 250 if adopting it mid-project). Default is 1.

**What number does a re-raised RFI get?** If an RFI is **re-raised on Fail or Redo**, it takes the **next available number** in the sequence — the old number is **not** reused.

### Can I edit the format later? **You can edit it** until the first RFI is raised **after configuration — after that the** format is locked.

### Can I use the same part twice? **No —** each part can be used only once.

### 💡 Good to know

-   RFI numbers run **sequentially across all checklists** in the project (one continuous sequence).
    
-   Once set, the RFI number appears in the **report, the web detail page, and the mobile checklist stage.**
    
-   Plan the format **before the first RFI** — it can't be changed once numbering has started.
    

### 🔗 Related articles

-   2.5.25 RFI Introduction and setup for the Project
    
-   2.5.26 Setup RFI stage for Project Checklist
    
-   2.5.23 Nomenclature — overview, create & import