description: "The RFI and Re-RFI workflows with diagrams: with/without approver, with/without inspection-stage approval, and Re-RFI On/Off. Maker raises RFI → (approver review) → Checker inspects → Pass/Approve moves on; Fail/Redo triggers a fresh RFI (Re-RFI On) or restarts from Inspection (Re-RFI Off)."
url: https://help.digiqc.com/hi/articles/160-2528-all-inspection-workflows-with-rfi
collection: "2.5 Web Setup, Monitoring, Tracking and Analysis"
updated: 2026-11-05
language: hi
alternates: [en]
---

# 2.5.28 All Inspection workflows with RFI

The RFI and Re-RFI workflows with diagrams: with/without approver, with/without inspection-stage approval, and Re-RFI On/Off. Maker raises RFI → (approver review) → Checker inspects → Pass/Approve moves on; Fail/Redo triggers a fresh RFI (Re-RFI On) or restarts from Inspection (Re-RFI Off).

### Overview

When RFI is enabled, an inspection can follow one of a few **RFI workflows**, depending on **(1)** whether an **RFI approver** is involved, **(2)** whether there is **approval at the checklist stage**, and **(3)** whether **Re-RFI** is On. This article explains those flows, with a diagram for each.

### 🧭 How the RFI workflow works

Terms used here: RFI Initiator (raises the RFI), Maker team (does the work), Checker (inspects), Approver (optional — accepts/rejects the RFI at Review, and/or approves after inspection).

1.  **Raise RFI** — the RFI Initiator requests inspection when work is ready.
    
2.  **Review RFI** _(only if an RFI approver is set)_ — the approver **Accepts** or **Rejects.** Reject → the RFI Initiator **rectifies** and raises a **fresh RFI.**
    
3.  **Inspection** — the Checker inspects → **Pass** or **Fail.**
    
4.  **Approval at checklist stage** _(if configured — up to 3 levels)_ — after a Pass, an approver **Approves** or gives **Redo.**
    
5.  **Fail or Redo** — what happens next depends on **Re-RFI** (below).
    

### Re-RFI — On vs Off

-   **Re-RFI On** _(default)_ — on a **Fail** or **Redo**, the RFI Initiator must raise a **fresh RFI (Re-RFI)** after corrections to restart.
    
-   **Re-RFI Off** — on a **Fail** or **Redo**, the process **restarts from the Checklist stage** — **no fresh RFI.**
    

### The RFI workflows

**1\. RFI → Inspection (Re-RFI On)** — no approver, no inspection approval. On a Fail, the RFI Initiator raises a fresh RFI.

![](https://hathi-jigar.github.io/userstory-reviews/scripts/workflow-diagrams/inspect/rfi-wf-1.png)

**2\. RFI → Inspection (Re-RFI Off)** — same, but on a Fail the inspection **restarts from the Checklist stage** (no fresh RFI).

![](https://hathi-jigar.github.io/userstory-reviews/scripts/workflow-diagrams/inspect/rfi-wf-2.png)

**3\. RFI → Inspection → Approval (Re-RFI On)** — the checklist stage has approval. A Fail or a Redo sends the RFI Initiator back to raise a fresh RFI.

![](https://hathi-jigar.github.io/userstory-reviews/scripts/workflow-diagrams/inspect/rfi-wf-3.png)

### 4\. RFI → Inspection → Approval (Re-RFI Off) **— with inspection approval, but a Fail or Redo** restarts from the Checklist stage.

![](https://hathi-jigar.github.io/userstory-reviews/scripts/workflow-diagrams/inspect/rfi-wf-4.png)

**5\. RFI (with Approver) → Inspection (Re-RFI On)** — an approver Accepts/Rejects the RFI first. Reject → Rectify RFI; Fail → fresh RFI.

![](https://hathi-jigar.github.io/userstory-reviews/scripts/workflow-diagrams/inspect/rfi-wf-5.png)

**6\. RFI (with Approver) → Inspection → Approval (Re-RFI On)** — the full chain, with **both** approval points (RFI Review and inspection Approval).

![](https://hathi-jigar.github.io/userstory-reviews/scripts/workflow-diagrams/inspect/rfi-wf-6.png)

### ❓ FAQ

#### 1\. What's the difference between RFI with and without an approver?

### With an approver**, the RFI is** accepted or rejected **at Review before inspection.** Without**, the RFI goes** straight to inspection.

#### What is "approval at the checklist stage"?

After the inspection **Passes**, an **approver** signs it off (up to **3 levels: L1 → L2 → L3**) before the stage completes. This is **separate** from the RFI approver.

#### On a Fail or Redo, what does Re-RFI On vs Off do?

**On** — the RFI Initiator raises a **fresh RFI.** **Off** — the process **restarts from the Checklist stage** (no fresh RFI).

#### What happens if the approver rejects the RFI?

The RFI Initiator **rectifies** and raises a **fresh RFI.**

#### Where's the complete list of inspection workflows?

See **2.2.13 digiQC Inspection Workflows** — the full 20-workflow catalogue (RFI and non-RFI).

### 💡 Good to know

-   RFI workflow depends on: **RFI approver** (no/yes) × **inspection-stage approval** (none / L1–L3) × **Re-RFI** (On/Off).
    
-   **Re-RFI On** (default) = fresh RFI after a Fail/Redo; **Off** = restart from the Checklist stage.
    
-   Re-RFI must be **enabled in the project RFI settings** (2.6.9).
    
-   The **full workflow catalogue** is in **2.2.13.**
    

### 🔗 Related articles

-   2.6.9 RFI Introduction and setup for the Project
    
-   2.6.10 Setup RFI stage for Project Checklist
    
-   2.2.13 digiQC Inspection Workflows
    
-   2.2.9 RFI process with Approver